181. Masked hypertension and chronic kidney disease: the role of out-of-office blood pressure monitoring.
Parati G, Ochoa JE, Stergiou G.
|
182. May Measurement Month 2017: an analysis of blood pressure screening results worldwide.
Beaney T, Schutte AE, Tomaszewski M, Ariti C, Burrell LM, Castillo RR, Charchar FJ, Damasceno A, Kruger R, Lackland DT, Nilsson PM, Prabhakaran D, Ramirez AJ, Schlaich MP, Wang J, Weber MA, Poulter NR.
|
183. Atrial Fibrillation Detection During 24-Hour Ambulatory Blood Pressure Monitoring: Comparison With 24-Hour Electrocardiography.
Kollias A, Destounis A, Kalogeropoulos P, Kyriakoulis KG, Ntineri A, Stergiou GS.
+ Εμφάνιση Περίληψης
This study assessed the diagnostic accuracy of a novel 24-hour ambulatory blood pressure (ABP) monitor (Microlife WatchBP O3 Afib) with implemented algorithm for automated atrial fibrillation (AF) detection during each ABP measurement. One hundred subjects (mean age 70.6±8.2 [SD] years; men 53%; hypertensives 85%; 17 with permanent AF; 4 paroxysmal AF; and 79 non-AF) had simultaneous 24-hour ABP monitoring and 24-hour Holter monitoring. Among a total of 6410 valid ABP readings, 1091 (17%) were taken in ECG AF rhythm. In reading-to-reading ABP analysis, the sensitivity, specificity, and accuracy of ABP monitoring in detecting AF were 93%, 87%, and 88%, respectively. In non-AF subjects, 12.8% of the 24-hour ABP readings indicated false-positive AF, of whom 27% were taken during supraventricular premature beats. There was a strong association between the proportion of false-positive AF readings and that of supraventricular premature beats (
|
184. Blood Pressure Measurement and Hypertension Diagnosis in the 2017 US Guidelines: First Things First.
Stergiou G, Palatini P, Asmar R, de la Sierra A, Myers M, Shennan A, Wang J, O'Brien E, Parati G.
|
185. Efficacy of anthropometric measures for identifying cardiovascular disease risk in adolescents: review and meta-analysis.
Lichtenauer M, Wheatley SD, Martyn-St James M, Duncan MJ, Cobayashi F, Berg G, Musso C, Graffigna M, Soutelo J, Bovet P, Kollias A, Stergiou GS, Grammatikos E, Griffiths C, Ingle L, Jung C.
|
186. Contributions of mean and shape of blood pressure distribution to worldwide trends and variations in raised blood pressure: a pooled analysis of 1018 population-based measurement studies with 88.6 million participants.
|
187. Office Blood Pressure Measurement: The Weak Cornerstone of Hypertension Diagnosis.
Stergiou G, Kollias A, Parati G, O'Brien E.
|
188. Validation of the iHealth ambulatory blood pressure monitor in adults according to the American National Standards Institute/Association for the Advancement of Medical Instrumentation/International Organization for Standardization standard.
Kollias A, Ntineri A, Kyriakoulis KG, Stambolliu E, Stergiou GS.
|
189. A Universal Standard for the Validation of Blood Pressure Measuring Devices: Association for the Advancement of Medical Instrumentation/European Society of Hypertension/International Organization for Standardization (AAMI/ESH/ISO) Collaboration Statement.
Stergiou GS, Alpert B, Mieke S, Asmar R, Atkins N, Eckert S, Frick G, Friedman B, Graßl T, Ichikawa T, Ioannidis JP, Lacy P, McManus R, Murray A, Myers M, Palatini P, Parati G, Quinn D, Sarkis J, Shennan A, Usuda T, Wang J, Wu CO, O'Brien E.
+ Εμφάνιση Περίληψης
In the past 30 years, several organizations, such as the US Association for the Advancement of Medical Instrumentation (AAMI), the British Hypertension Society, the European Society of Hypertension (ESH) Working Group on Blood Pressure (BP) Monitoring, and the International Organization for Standardization (ISO), have developed protocols for clinical validation of BP measuring devices. However, it is recognized that science, as well as patients, consumers, and manufacturers, would be best served if all BP measuring devices were assessed for accuracy according to an agreed single validation protocol that had global acceptance. Therefore, an international initiative was taken by the AAMI, ESH, and ISO experts who agreed to develop a universal standard for device validation. This statement presents the key aspects of a validation procedure, which were agreed by the AAMI, ESH, and ISO representatives as the basis for a single universal validation protocol. As soon as the AAMI/ESH/ISO standard is fully developed, this will be regarded as the single universal standard and will replace all other previous standards/protocols.
|
190. Improving the accuracy of blood pressure measurement: the influence of the European Society of Hypertension International Protocol (ESH-IP) for the validation of blood pressure measuring devices and future perspectives.
Stergiou GS, Asmar R, Myers M, Palatini P, Parati G, Shennan A, Wang J, O'Brien E.
|
191. A universal standard for the validation of blood pressure measuring devices: Association for the Advancement of Medical Instrumentation/European Society of Hypertension/International Organization for Standardization (AAMI/ESH/ISO) Collaboration Statement.
Stergiou GS, Alpert B, Mieke S, Asmar R, Atkins N, Eckert S, Frick G, Friedman B, Graßl T, Ichikawa T, Ioannidis JP, Lacy P, McManus R, Murray A, Myers M, Palatini P, Parati G, Quinn D, Sarkis J, Shennan A, Usuda T, Wang J, Wu CO, O'Brien E.
+ Εμφάνιση Περίληψης
: In the last 30 years, several organizations, such as the US Association for the Advancement of Medical Instrumentation (AAMI), the British Hypertension Society, the European Society of Hypertension (ESH) Working Group on Blood Pressure (BP) Monitoring and the International Organization for Standardization (ISO) have developed protocols for clinical validation of BP measuring devices. However, it is recognized that science, as well as patients, consumers and manufacturers would be best served if all BP measuring devices were assessed for accuracy according to an agreed single validation protocol that had global acceptance. Therefore, an international initiative was taken by AAMI, ESH and ISO experts who agreed to develop a universal standard for device validation. This statement presents the key aspects of a validation procedure, which were agreed by the AAMI, ESH and ISO representatives as the basis for a single universal validation protocol. As soon as the AAMI/ESH/ISO standard is fully developed, this will be regarded as the single universal standard and will replace all other previous standards/protocols.
|
192. Validation of the professional device for blood pressure measurement Microlife WatchBP Office in adults and children according to the American National Standards Institute/Association for the Advancement of Medical Instrumentation/International Organization for Standardization standard.
Kollias A, Ntineri A, Kyriakoulis KG, Stambolliu E, Lagou S, Boubouchairopoulou N, Stergiou GS.
|
193. Blood pressure monitoring: theory and practice. European Society of Hypertension Working Group on Blood Pressure Monitoring and Cardiovascular Variability Teaching Course Proceedings.
Stergiou GS, Palatini P, Asmar R, Bilo G, de la Sierra A, Head G, Kario K, Mihailidou A, Wang J, Mancia G, O'Brien E, Parati G.
+ Εμφάνιση Περίληψης
The European Society of Hypertension (ESH) Working Group on Blood Pressure (BP) Monitoring and Cardiovascular Variability organized a Teaching Course on 'Blood Pressure Monitoring: Theory and Practice' during the 2017 ESH Meeting in Milan, Italy. This course performed by 11 international BP monitoring experts covered key topics of BP monitoring, including office BP measurement, ambulatory BP monitoring, home BP monitoring, ambulatory versus home BP, white-coat and masked hypertension, cuff use, and BP variability. This article presents a summary of the proceedings of the ESH BP Monitoring Teaching Course, including essential information, practical issues, and recommendations on the clinical application of BP monitoring methods, aiming to the optimal management of patients with suspected or diagnosed hypertension.
|
194. Worldwide trends in body-mass index, underweight, overweight, and obesity from 1975 to 2016: a pooled analysis of 2416 population-based measurement studies in 128·9 million children, adolescents, and adults.
|
195. Treating Visit-to-Visit Blood Pressure Variability to Improve Prognosis: Is Amlodipine the Drug of Choice?
Kollias A, Stergiou GS, Kyriakoulis KG, Bilo G, Parati G.
|
196. The optimal night-time home blood pressure monitoring schedule: agreement with ambulatory blood pressure and association with organ damage.
Kollias A, Andreadis E, Agaliotis G, Kolyvas GN, Achimastos A, Stergiou GS.
|
197. Pharmacy blood pressure: a common, useful, and neglected out of office blood pressure measurement method.
Stergiou GS, Kyriakoulis KG, Kollias A.
|
198. Differential associations of systolic and diastolic time rate of blood pressure variation with carotid atherosclerosis and plaque echogenicity.
Kolyviras A, Manios E, Georgiopoulos G, Michas F, Gustavsson T, Papadopoulou E, Ageliki L, Kanakakis J, Papamichael C, Stergiou G, Zakopoulos N, Stamatelopoulos K.
+ Εμφάνιση Περίληψης
In the current study, the authors sought to assess whether the time rate of systolic and diastolic blood pressure variation is associated with advanced subclinical stages of carotid atherosclerosis and plaque echogenicity assessed by gray scale median. The authors recruited 237 consecutive patients with normotension and hypertension who underwent 24-hour ambulatory blood pressure monitoring and carotid artery ultrasonography. There was an independent association between low 24-hour systolic time rate and increased echogenicity of carotid plaques (adjusted odds ratio for highest vs lower tertiles of gray scale median, 0.470; 95% confidence interval, 0.245-0.902 [P = .023]). Moreover, increased nighttime diastolic time rate independently correlated with the presence (adjusted odds ratio, 1.328; P = .015) and number of carotid plaques (adjusted odds ratio, 1.410; P = .003). These results indicate differential associations of the systolic and diastolic components of time rate of blood pressure variation with the presence, extent, and composition of carotid plaques and suggest that when blood pressure variation is assessed, both components should be considered.
|
199. Prognostic value of average home blood pressure and variability: 19-year follow-up of the Didima study.
Ntineri A, Kalogeropoulos PG, Kyriakoulis KG, Aissopou EK, Thomopoulou G, Kollias A, Stergiou GS.
|
200. Visit-to-Visit Office Blood Pressure Variability and Cardiovascular Outcomes in SPRINT (Systolic Blood Pressure Intervention Trial).
Chang TI, Reboussin DM, Chertow GM, Cheung AK, Cushman WC, Kostis WJ, Parati G, Raj D, Riessen E, Shapiro B, Stergiou GS, Townsend RR, Tsioufis K, Whelton PK, Whittle J, Wright JT, Papademetriou V.
|