401. Assessment of drug effects on blood pressure and pulse pressure using clinic, home and ambulatory measurements.
Stergiou GS, Efstathiou SP, Skeva II, Baibas NM, Kalkana CB, Mountokalakis TD.
+ Εμφάνιση Περίληψης
This study investigated the differences in the effect of an angiotensin converting enzyme inhibitor (ACEI) compared with an angiotensin receptor blocker (ARB) on blood pressure (BP) and pulse pressure (PP) measured in the clinic (CBP and CPP, respectively), at home (HBP, HPP) and with ambulatory monitoring (ABP, APP). Twenty-seven hypertensive patients were randomised to receive lisinopril (20 mg) or losartan (50 mg) for 5 weeks, and were subsequently crossed-over to the alternative treatment for a second 5-week period. Measurements of CBP, 24-h ABP and 5-days HBP were performed before randomisation and at the end of each treatment period. All measurement methods showed that lisinopril was more effective than losartan in reducing BP. However, the difference between the two drugs was demonstrated with greater precision using HBP (P<0.001) than 24-h ABP (P<0.01), whereas the poorest precision for demonstrating this difference was provided by CBP (P<0.05). Lisinopril was also found more effective than losartan in reducing HPP (P=0.01) and 24-h APP (P=0.03) whereas no such a difference was detected using measurements of CPP. It was concluded that the antihypertensive drugs may differ in their effects not only on BP, but also on PP. HBP monitoring appears to be as reliable as 24-h ABP monitoring in detecting differences in the effect of drugs on both BP and PP. Clinic measurements seem to be the least reliable method, particularly in the detection of differences in PP.
|
402. Determinants of arterial stiffness in Greek and French hypertensive men.
Achimastos A, Benetos A, Stergiou G, Argyraki K, Karmaniolas K, Thomas F, Mountokallakis T.
+ Εμφάνιση Περίληψης
The aim of the present study was to assess the main determinants of arterial stiffness in Greek and French middle-aged, hypertensive men, by using pulse wave velocity (PWV) measurements, which is an established method of quantification of arterial stiffness. The study was performed in 83 consecutive Greek and 79 consecutive French untreated male hypertensive outpatients aged 45-65 years. French subjects were examined in Paris at the "Centre d'Investigations Préventives et Cliniques" (the IPC Center). Greek patients were examined in Athens at the hypertension outpatient clinic in Sotiria Hospital (University of Athens). In both Greek and French hypertensive subjects, aortic stiffness was determined by the same parameters: age, blood pressure and heart rate (HR) explained approximately 40% of the aortic PWV variations, whereas lipids, triglycerides and tobacco smoking were not significant associated with aortic stiffness. After multivariate adjustments, Greek hypertensives had higher aortic stiffness as compared to the French patients by 1.2 m/s (approximately 10%); p < 0.001. Greek hypertensive subjects had also a higher body weight, waist, HR and prevalence of smoking. However, among all these factors only HR had a significant effect on PWV. Also after adjustment for HR, the difference in PWV between the two populations persisted. In conclusion, in two different populations, stiffness seems to be regulated by the same major factors. The higher aortic stiffness found in Greek hypertensives may be explained by the presence of other non-evaluated risk factors and/or patient selection differences.
|
403. Clinic, home and ambulatory pulse pressure: comparison and reproducibility.
Stergiou GS, Efstathiou SP, Argyraki CK, Gantzarou AP, Roussias LG, Mountokalakis TD.
|
404. Effect of estrogen receptor modulator tamoxifen on blood pressure, plasma renin activity, and renal sodium excretion.
Stergiou GS, Zourbaki AS, Efstathiou SP, Stathopoulos GP, Keramopoulos AD, Mountokalakis TD.
|
405. Task Force II: blood pressure measurement and cardiovascular outcome.
Staessen JA, Asmar R, De Buyzere M, Imai Y, Parati G, Shimada K, Stergiou G, Redón J, Verdecchia P.
|
406. Parallel morning and evening surge in stroke onset, blood pressure, and physical activity.
Stergiou GS, Vemmos KN, Pliarchopoulou KM, Synetos AG, Roussias LG, Mountokalakis TD.
|
407. Self blood pressure monitoring at home by wrist devices: a reliable approach?
Parati G, Asmar R, Stergiou GS.
|
408. Reproducibility of home, ambulatory, and clinic blood pressure: implications for the design of trials for the assessment of antihypertensive drug efficacy.
Stergiou GS, Baibas NM, Gantzarou AP, Skeva II, Kalkana CB, Roussias LG, Mountokalakis TD.
|
409. Does European or non-European origin influence health care and prognosis for HIV patients in Europe? The EuroSIDA Study Group.
Blaxhult A, Mocroft A, Phillips A, van Lunzen J, Bentwich Z, Stergiou G, Colebunders R, Benfield TL, Mulcahy F, Lundgren JD.
|
410. Does the antihypertensive response to angiotensin converting enzyme inhibition predict the antihypertensive response to angiotensin receptor antagonism?
Stergiou GS, Skeva II, Baibas NM, Kalkana CB, Roussias LG, Mountokalakis TD.
+ Εμφάνιση Περίληψης
To test the hypothesis that the antihypertensive response to angiotensin converting enzyme (ACE) inhibition can predict the response to angiotensin II type I receptor (AT1R) antagonism, 33 hypertensive patients were randomized to receive lisinopril (20 mg) or losartan (50 mg) for 5 weeks. Patients were then crossed-over to the alternative treatment for a second 5-week period. Twenty-four-hour ambulatory BP (ABP) was measured before randomization and on the final day of each period. The agreement in ABP response between the two drugs was assessed using the following approaches: Subjects were classified as responders and nonresponders using as a threshold an arbitrary level of response (ABP fall > or = 10 mm Hg systolic or > or = 5 mm Hg diastolic) or the median ABP response achieved by each of the drugs. Disagreement between the two drugs in the responders-nonresponders classification was expressed as the proportion of subjects whose ABP responded to one of the drugs only. Lisinopril was more effective than losartan in reducing ABP (mean difference 4.7+/-8.1/3.3+/-5.7 mm Hg, systolic/diastolic, P < .05). Disagreement in the antihypertensive response between the two drugs was found in 39%/33% of subjects for systolic/diastolic ABP using the arbitrary response criterion (33%/39% using the median response criterion). Significant correlations were found between the responses to lisinopril and losartan (r = 0.47/0.59, systolic/diastolic, P < .01). We conclude that in more than one third of hypertensive subjects, the BP response to ACE inhibition fails to predict the response to AT1R antagonism and vice versa. These data suggest that there are differences between these two drug classes that are not only of theoretical but also of practical significance.
|
411. Diagnosis of hypertension using home or ambulatory blood pressure monitoring: comparison with the conventional strategy based on repeated clinic blood pressure measurements.
Stergiou GS, Skeva II, Baibas NM, Kalkana CB, Roussias LG, Mountokalakis TD.
|
412. Home blood pressure normalcy: the Didima study.
Stergiou GS, Thomopoulou GC, Skeva II, Mountokalakis TD.
+ Εμφάνιση Περίληψης
To evaluate reference values of home blood pressure (HBP) a cross-sectional community study was conducted on 694 adult subjects (aged > or = 18 years) of the village Didima in southern Greece (participation rate 76.4%). Clinic blood pressure (CBP) was measured on two visits (triplicate measurements, mercury sphygmomanometer) and HBP on 3 workdays (duplicate morning and evening measurements, oscillometric devices; Omron HEM 705CP). After exclusion of 132 subjects (103 treated hypertensives and 29 with incomplete data), 562 subjects were analyzed (mean +/- SD aged 51.2 +/- 17.2 years, 42.7% men). Average HBP (120.0 +/- 17.8/72.6 +/- 8.8 mm Hg, systolic/diastolic) was strongly correlated (P < .0001) with CBP (118.7 +/- 17.7/73.8 +/- 10.5 mm Hg). Systolic CBP was 1.3 mm Hg lower than HBP (P < .01, 95% confidence interval 0.4, 2.2), whereas diastolic CBP was 1.2 mm Hg higher than HBP (P < .0001, 95% confidence interval 0.6, 1.7). The threshold of HBP normality determined using three different approaches was 1) 139.7/83.0 mm Hg (systolic/diastolic) using the distribution criterion (95th percentile of the HBP distribution among 476 normotensive subjects); 2) 139.7/85.8 mm Hg using the correspondence criterion (the percentiles of the CBP distribution that correspond to CBP > or = 140/90 mm Hg were estimated, and the levels of BP that correspond to these same percentiles on the HBP distribution were calculated); and 3) 137.4/82.7 mm Hg using the regression criterion (calculation of the levels of HBP that correspond to CBP of 140/90 mm Hg using the regression equation between HBP and CBP). Overall, the findings of the three criteria suggest that average HBP < 137/82 mm Hg might be considered as probably normal, > 140/86 mm Hg as probably abnormal, and within these limits as borderline. Until mortality-based prospective data are available, this approach might be useful in the interpretation of HBP in clinical practice.
|
413. Additive hypotensive effect of angiotensin-converting enzyme inhibition and angiotensin-receptor antagonism in essential hypertension.
Stergiou GS, Skeva II, Baibas NM, Roussias LG, Kalkana CB, Achimastos AD, Mountokalakis TD.
+ Εμφάνιση Περίληψης
The study was designed to assess the antihypertensive effect of combined angiotensin-converting enzyme (ACE) inhibition and angiotensin II type 1 receptor (AT1) antagonism in patients with essential hypertension. Twenty patients with uncontrolled ambulatory diastolic blood pressure (BP) after 6 weeks of ACE inhibitor monotherapy (benazepril, 20 mg, o.d.) were randomized to receive double-blind valsartan, 80 mg, o.d. (AT1 antagonist) or matching placebo for 5 weeks while continuing to receive background benazepril. Then patients crossed over to the alternative regimen for a second 5-week period. The 24-h ambulatory BP was monitored on the final day of the benazepril monotherapy period and on the final day of each double-blind treatment period. Valsartan added to benazepril produced a significant antihypertensive effect with a benefit over placebo of 6.5 +/- 12.6/4.5 +/- 8.0 mm Hg (systolic/diastolic) for average awake ambulatory BP (p < 0.05), 7.1 +/- 9.4/5.6 +/- 6.5 mm Hg for asleep BP (p < 0.01), and 6.8 +/- 9.7/4.9 +/- 6.8 mm Hg for average 24-h ambulatory BP (p < 0.01). Pulse rate was unaffected. Plasma active renin was higher on the benazepril-valsartan combination compared with benazepril-placebo (p < 0.05). There was no change in routine biochemical variables when valsartan was added to benazepril. Six patients reported mild dizziness or fatigue (three also with placebo). These data suggest that in hypertensive patients uncontrolled with an ACE inhibitor, the addition of an AT1 antagonist provides a powerful and safe antihypertensive drug combination.
|
414. Consensus Conference on Self-blood pressure measurement. Clinical applications and diagnosis.
Herpin D, Pickering T, Stergiou G, de Leeuw P, Germano G.
+ Εμφάνιση Περίληψης
The present study was aimed at reviewing the medical literature devoted to the clinical applications of self-blood pressure monitoring (SBPM) and at providing some recommendations regarding the use of SBPM for diagnostic purposes. The lack of reliability of conventional blood pressure (BP) measurement is largely related to the extreme variability of BP over time. SBPM provides a large number of readings and can be used to predict the results of repeated clinical measurements. The use of SBPM in the diagnosis of white coat hypertension can be proposed as a screening test: if it gives a positive result (a low home BP), it should be confirmed by ambulatory BP monitoring (ABPM). SBPM could improve patients' compliance with medication. Last, SBPM may be cost-effective for the management of hypertensive patients, by reducing costs of medication, number of clinic visits and costs of cardiovascular morbidity. Compared with ABPM, SBPM seems to have a less value for the initial diagnosis of hypertension and for predicting prognosis. In contrast, it should be of more value for the long term follow-up of patients with white coat hypertension and for the evaluation of treatment efficacy in patients with sustained hypertension. The use of SBPM in diabetic hypertensives, in pregnant women and in the elderly is encouraged, but needs further evaluation.
|
415. Detection of non-dipper hypertensives in clinical practice: does it really matter?
Stergiou GS, Mountokalakis TD.
|
416. Prevalence, awareness, treatment, and control of hypertension in Greece: the Didima study.
Stergiou GS, Thomopoulou GC, Skeva II, Mountokalakis TD.
+ Εμφάνιση Περίληψης
To assess the prevalence and the levels of awareness, treatment, and control of hypertension in the rural population of Greece, a cross-sectional survey of the total population age > or =18 years of the village Didima was conducted. The survey included an interview and blood pressure (BP) measurement on two clinic visits. Hypertension was defined as systolic BP > or = 140 mm Hg and or diastolic BP > or = 90 mm Hg or current treatment with antihypertensive drugs. The same BP threshold was used for the assessment of hypertension control. A total of 694 inhabitants participated (response rate 76.4%), and 665 were analyzed. The prevalence of hypertension was 28.4% (men 30.2%, women 27.1%). Of the subjects age > or =65 years, 50% had hypertension. Although 73% of participants were measuring their BP at least once a year, overall, 39.2% of hypertensives were unaware of the diagnosis (men 50%, women 30.5%), 6.3% were aware but not treated (men 4.8%, women 7.6%), 27.5% were treated but not controlled (men 22.6%, women 31.4%), and 27% were treated and controlled (men 22.6%, women 30.5%). These results suggest that, in the rural population of Greece, hypertension is a common risk factor with considerable potential for improvement in levels of control.
|
417. The international database of self-recorded blood pressures in normotensive and untreated hypertensive subjects.
Thijs L, Staessen JA, Celis H, Fagard R, De Cort P, de Gaudemaris R, Enström I, Imai Y, Julius S, Ménard J, Mion D, Palatini P, Rosenfeld J, Shapiro D, Spence D, Stergiou G.
|
418. White coat effect detected using self-monitoring of blood pressure at home: comparison with ambulatory blood pressure.
Stergiou GS, Zourbaki AS, Skeva II, Mountokalakis TD.
+ Εμφάνιση Περίληψης
The objective of the study was to investigate whether home blood pressure (HBP) is a reliable alternative to ambulatory blood pressure (ABP) for the detection of the white coat effect (WCE). Hypertensive patients were randomized to measure HBP for 2 weeks or ABP for 24 h. The alternative measurement was then performed. Clinic blood pressure (CBP) was measured in the beginning and end of the study. Subjects with a difference of > or = 20 mm Hg systolic or > or = 10 mm Hg diastolic BP between CBP and awake ABP or CBP and HBP, were classified as clinic reactors. A total of 189 patients completed the study (79 on stable antihypertensive treatment). There was no difference in the magnitude of WCE assessed using the ABP or the HBP method (mean discrepancy, systolic BP: -1.5 +/- 11.7 mm Hg, 95% CI -3.2, 0.2; diastolic BP: 0.9 +/- 7.0, 95% CI -0.1, 1.9). A strong association existed between WCE calculated using the HBP or the ABP method (r = 0.64/0.59 systolic/diastolic, P < .001). The proportion of patients classified as clinic reactors was identical using the HBP or the ABP method (25.9%). Agreement between methods in the classification of clinic reactors was found in 147 patients (78%). The sensitivity and specificity of the HBP method to classify correctly clinic reactors (ABP method used as the standard) were 57% and 85%, respectively, whereas its positive and negative predictive value were 57% and 85%. These results indicate that HBP is not appropriate as an alternative to ABP diagnostic testing in the detection of WCE. Nevertheless, HBP appears useful as a screening test for the detection of this phenomenon.
|
419. Self-monitoring of blood pressure at home: how many measurements are needed?
Stergiou GS, Skeva II, Zourbaki AS, Mountokalakis TD.
|
420. Home self-monitoring of blood pressure: is fully automated oscillometric technique as good as conventional stethoscopic technique?
Stergiou GS, Voutsa AV, Achimastos AD, Mountokalakis TD.
+ Εμφάνιση Περίληψης
Home blood pressure (HBP) measurement is becoming increasingly popular as an additional source of information for the practicing physician. Whether HBP measured with a fully automated oscillometric device (oHBP) is more reliable than HBP measured with an aneroid sphygmomanometer and a stethoscope (sHBP) remains unclear. We compared sHBP with oHBP using as a reference method daytime ambulatory blood pressure (ABP), as this is believed to be a better index of an individual's overall level of pressure. Forty-six hypertensive patients measuring HBP with aneroid devices were retrained by a standard 30 min protocol that included training in the technique of measurement, checking patients' devices, and testing patients' performance in stethoscopic measurement. Patients were randomized to measure for 2 weeks either sHBP using their own calibrated aneroid devices or oHBP using a validated fully automated oscillometric device (Omron HEM-705CP). Then 24 h ABP monitoring was performed (SpaceLabs 90207) and patients crossed over for a second 2 week period by using the alternative HBP measurement technique. Mean sHBP was not different from mean oHBP, and there was a close correlation between them (r = 0.82/0.76 for systolic/diastolic BP, P < .001). Daytime ABP was not different from oHBP or sHBP and was closely related to both of them (oHBP, r = 0.59/0.72 systolic/diastolic BP, P < .001; sHBP, 0.50/0.65, P < .001). Age was significantly related with diastolic ABP-sHBP difference (r = 0.33, P < .05). These results suggest that HBP measured with validated fully automated oscillometric devices is equally reliable in predicting average ABP as that measured with calibrated aneroid sphygmomanometers used by very carefully trained patients. In clinical practice, HBP monitoring by using reliable automated devices is probably more feasible than to achieve a high standard of stethoscopic HBP measuring technique.
|